3rd Draft - December 23, 2009 Residential Program - NEW CONSTRUCTION: All new construction projects, excluding LEED (with # energy and # water points (state how many points or what level of certification), are required to comply with the following sections. The exemptions listed above must show their intent to meet the requirements at the building permit review stage and receive final certification under the applicable program, prior to receiving a certificate of occupancy. (Need to determine if any additional programs would be suitable for an exemption.)
Monday, February 08 2010
Meeting Minutes BuildSmart Technical Advisory committee January 27, 2010 Old County Courthouse 5:30 pm - 7:00 pm
Present: Brain Poster, Alan Richardson, Hermie Havvic, Matt Holland, Seth Westbrook, Mark Goodman, Tim Carter, Alan Stark, Pete Schwartz, Bruce Tidwell, Shana Sweitzer
Old Business: 1. Brian Bennet makes a Motion to adopt January 6, 2010 meeting minutes. Alan Richardson seconds. Unanimous vote to adopt the January 6, 2010 meeting minutes.
Monday, February 08 2010
Meeting Minutes BuildSmart Technical Advisory committee January 6, 2010 Old County Courthouse 5:30 pm - 7:00 pm
Present: David Lister, Joe Marx, Tim Carter, Brian Poster, Pete Schwartz, Don Nurge, Bruce Tidwell, Tom Harned, Rick Stark, Shana Sweitzer, Seth Westbrook Bruce Tidwell makes motion to adopt minutes from December 16th meeting. Brian Poster seconds the motion. Unanimous vote to adopt minutes. Discuss Hailey Green Building and Development Committee presentation to BSTAC on January 20, 2010.Monday, February 08 2010
Meeting Minutes: BuildSmart Technical Advisory Committee December 16, 2009 5:30 pm - 6:30 pm Old Business Review meeting minutes. In reality, we are looking at simple payback not ROI. ROI compares investment between two or more possibilities. MOTION: Rick Stark moves to adopt minutes from December 2nd and December 9th meeting with amended changes. Brain Bennet seconds. Meetings moved to first and third Wednesday of every month and expand meeting time to 1 ½ hrs.New Business 1. Review Rick Stark's Proposal for Additions and HERS requirements. Comments: Simple and easy to understand Meets the 30% goal. Seems fair and equitable Need to have a bottom HERS threshold for existing structure. Don't want to punish the guy who built a 60 HERS home two years ago and now wants to add on an additional garage and needs to get his existing sq ft a 30% improvement. 70 may be an appropriate threshold considering that is where is 30% improvement above IECC. What about the guy who is building a garage on? Would he need to improve the existing house? If the goal is to improve existing structures an "exception" does not seems appropriate.Rick will take comments and bring another proposal forward. 2. Tom Harned HERS Q&A session: Energy Audit's; Energy Audits do not require use of a program, but HERS does. No national standard; varies types of energy audits. Some audits are walk through only while other audits conduct blow door, duct blaster, thermal photography to identify specific problems of the structure. Specific to the needs or concerns of each specific home i.e. cold rooms or drafts Identifies health concerns associated with tightening the BE. Looks at simple payback, does equations by hand Looks at safety and backdraftingHERS Utilizes a software program to project performance for new construction and existing construction. Also involves a performance tests to ensure performance projections occur. HERS raters are certified by a national organization. Quality assurance. Code of ethics. Requires three months of coursework and field practicals. Looks at the overall performance of the structure, does not look at one aspect of the structure such a BE tightness or mechanical efficiency. Looks at simple payback, does equations via the software program. Also applies the simple payback as a function of overall performance, while audit assess payback per specific improvement. HERS takes into consideration the local climate and number of heating days in your local Provides a comparison between homes while an audit just looks at how to improve the energy efficiency of the existing home. RESNET looks at energy only while Building Performance Institute looks at health and safety. Provides a projection HERS score based on plans and a confirmed HERS score based on a blower door and duct blaster test.Does HERS take into consideration snow load building? Yes, it can take into consideration extra mass and bridging. HERS gives an R value for everything in a wall. Looks R-value wall by wall, that is why a larger house with many corners can take longer and cost more than smaller simpler designed homes.Does air conditioning affect HERS score? Yes, if you don't have air conditioning then your home performs better, consequently giving you a better HERS score if you did have air conditioning.Does the type of radiant heating get brought into calculations? No, HERS looks at the source of heat for floor, not the implementation or design.HERS has a simplified and detailed program. The simplified has less detail on the mechanical and solar aspects.HERS provides various types of reports for the homeowner or contractor to make informed decisions, not just a HERS number. Creation of some reports take additional time by the HERS rating and consequently may cost additional beyond the actual HERS rating. Examples of reports are as follows: "Performance Summary", "Emissions Report", Component Loads, Component Design, Air Leakage Report, Economic Summary, Performance SummaryHERS will identify rebates available for various improvements. The rater will have to be aware of these to apply them. Mechanical equipment and BE are large focuses in the HERS program.
Comments: Having a County building inspector familiar with HERS and building science will provide additional guidance to builder and help ensure HERS score and suggested energy improvements are fair and consistent. Can HERs rater be familiar with project to provide suggestions to improve the HERS score by just looking at the plans? Brian Bennet, YES.Once the contractors and architects get familiar with HERS they will see "points" when they remodel or create new construction. Improvements are not hidden. Next Meeting January 6, 2010 Summary and Comparison of Various Options for Additions and HERS:RS Option: Requires a HERS for the entire structure, new and existing sq ft, based on the following Existing structure; 30% improvement to current HERS rating. Addition; new sq ft meets new construction HERS requirements based on the amount of sq ft being added. Additions that involve a 50% sq ft increase will be required to meet the new construction HERS sliding scale for the entire home. Two HERS scores are required, one is pre-permit for the existing structure, the second a post-construction performance HERS rating.Example A: 4000 sq ft home with a pre-addition HERS rating of 200. 800 sq ft addition requires a 70 HERS (per new construction sliding scale). The post-addition home will be required to meet a 128.3 HERS rating for the entire structure. ((4000)(HERS 140)) + (((800)(HERS(70)) = 4800 X 616,000/4800 = 128 HERS for the entire structure AR Option: Two possible paths to compliance. Path I Additions; the new sq ft would be required to meet a HERS rating based on the entire sq ft, per the new construction sliding scale. Existing Structure: no improvement to existing structure.Example A: 4000 sq ft home applies for a 800 sq ft addition. Per the new construction sliding HERS scale a 4800 sq ft home is required to meet a 58.5 HERS. The sq ft for the new addition will be required to meet a 58.5 HERS rating. No improvements will be required for the existing home. Path II Requires a HERS for the entire structure, new and existing sq ft, based on the following formula and the new construction sliding HERS sliding scale; ((HERS Rating for the new sq ft) X (.20)) + ((HERS rating for the existing sq ft) X (.80)) = HERS rating for the entire structure One HERS rating will be required post-construction.Example A - 4000 sq ft home applies for an 800 sq ft addition; ((80 X 62.5 HERS) + (70 HERS X .20)) = 64 HERS for the entire structure. Boulder Option: Uses a separate sliding scale based on existing size of the structure and % of structure which is being renovated or % of increase to the existing footprint. Boulder County is currently in the process of replacing this process. Example A - 4000 sq ft home applies for a 800 sq ft addition. Entire structure must meet an 80 HERSMonday, January 11 2010
DRAFT MEETING MINUTES BuildSmart Technical Advisory Committee October 5, 2009 5:30 pm - 6:30 pm
Present: Don Nurge, Rick Stark, Brain Bennett, Hermie Haavik, Tor Jensen, Garth Callaghan, Stephanie Reid, Muriel Plat, Alan Richardson, Bruce Tidwell, Shana Sweitzer, Mike Morgan (?)
Old Business Review the IAQ and Site Goals. They are stated as proposed.Tuesday, October 20 2009
BSTAC Recommended Goals for a Green Building Program in Blaine County Idaho Energy Goals New Construction
Friday, October 09 2009
October 12th The Integrated Design Process Using Home Energy Rating Systems (HERS) to obtain greater Energy Efficiency Presented and Facilitated by David Neiger - Populus Sustainable Design Consulting, Boulder CO
Community Campus - Room 301/302
Presentation 5:30-6:30PM (open to all)
Energy Modeling Charrette 6:30-8:30PM (limited space available for non AIA members, RSVP 788-9815 x24) *3 CEUs will be available to attending AIA members (Professionals involved in the design and building industry are encouraged to attend) October 13, 2009 Creating a Green Building Program A presentation to Blaine County's Board of Commissioners and the City of Hailey's Mayor and Council Presented by David Neiger - Populus Sustainable Design Consulting, Boulder CO Boulder City and Boulder County, CO's experience with adopting and implementing a green building program.
5:30-7:00pm Hailey City Hall - Council Chambers THE PUBLIC IS ENCOURAGED TO ATTEND!Thursday, September 24 2009
BuildSmart Technical Advisory Committee August 31, 2009 Old Business 1. Discuss and Adopt August 24, 2009 meeting minutes. 2. Plum TV - group of private businesses and Blaine County go into together to do a weekly or daily "green building" tip. Exposure for private businesses and supports education outreach goals of BSTAC
Thursday, September 17 2009
Sustainable Building and Planning Advisory Committee September 2, 2009 - Meeting Summary 1. New Business I. Reviewed updated survey rankings and discussed building program components a) Ideas about commercial remodels: Wednesday, September 16 2009
AGENDA BuildSmart Technical Advisory Committee August 31, 2009 5:30 pm - 6:30 pm
Friday, August 28 2009
Draft Meeting Minutes BuildSmart Technical Advisory Committee August 24, 2009 5:30 pm - 6:30 pm Old Business August 10, 2009 Meeting minutes were adopted: Bruce Tidwell motioned, Garth Callaghan seconded.Friday, August 28 2009
Sustainable Building and Planning Advisory Committee August 19, 2009 - Meeting Summary 1. Old Business I. Committee members shared information gathered from their respective assignments.
Thursday, August 27 2009
Draft Goals For a Green Building Program in Blaine County Energy Goals New Construction 1. Increase the energy efficiency of new construction by 30% above the current IECC.
Thursday, August 20 2009
Draft Meeting Minutes BuildSmart Technical Advisory Committee August 10, 2009 5:30 pm - 6:30 pm Old Business Outreach and Education Activities: Thursday, August 20 2009
Sustainable Building and Planning Advisory Committee August 19, 2009 - Meeting Summary [issuu viewmode=presentation layout=http%3A%2F%2Fskin.issuu.com%2Fv%2Flight%2Flayout.xml showflipbtn=true documentid=090819235534-6291bffd9f984dc683ac2cc3defce565 docname=greenbuildingsummit-brief username=ercsv loadinginfotext=Santa%20Fe%20Green%20Building%20Code showhtmllink=true tag=presentation width=420 height=315 unit=px] Wednesday, August 19 2009
|